• 短篇论著 •    

支气管胸膜瘘电子支气管镜介入治疗的临床分析

李艳   

  1. 湖北省襄阳市中心医院
  • 收稿日期:2011-03-21 修回日期:2011-09-01 出版日期:2012-01-15 发布日期:2012-01-15
  • 通讯作者: 李艳

Clinical analysis of interventional treatment on the bronchosocpy fistula by electronic bronchosocpy

  • Received:2011-03-21 Revised:2011-09-01 Published:2012-01-15 Online:2012-01-15

摘要: 目的:探讨经电子支气管镜注入康派特医用胶治疗支气管胸膜瘘的临床效果。方法:对23例支气管胸膜瘘患者经电子支气管镜注入康派特医用胶治疗,瘘口大小2-10mm,平均4.1mm。术后继续加强抗感染、加强支持对症治疗。结果:复查支气管镜可以看到瘘口在4mm以内的15例全部痊愈,5例瘘口在4-7mm的经2-3次治疗4例痊愈,1例无效,3例瘘口在7-10mm经多次治疗仅1例痊愈,2例无效。结论:支气管胸膜瘘经电子支气管镜注入康派特医用胶治疗,操作简单、安全、疗效显著,损伤小,值得临床广泛推广。

关键词: 电子支气管镜, 支气管胸膜瘘, 康派特医用胶

Abstract: Objective:To observe the role of Compont Medical Adhesive to the bronchosocpy fistula(BPF) patients infused by electronic bronchosocpy. Methods:In our study, 23 BPF patients were treated by infused Compont Medical Adhesive by electronic bronchosocpy.The fistula were from 2 to 10mm,and were 4.1mm at average.All patients continued to strengthen anti-infection and supportive treatments at postoperative.Results: We reviewed all patients by electronic bronchosocpy.The 15 patients which their fistula were less than 4mm were healed. Four of the 5 patients which their fistula were from 4 to 7mm were healed by 2 to 3 times treatment.One of their 5 patients was invalid. And only one of 3 patients which their fistula were from 7 to 10mm was healed by several times treatment. Two of their 3 patients were invalid.Conclusion: The treatment of Compont Medical Adhesive infused by electronic bronchosocpy to the BPF patients is a simple,little injury,safe and effective method to and can be preffered.

Key words: Electronic bronchosocpy, Bronchosocpy fistula, Compont Medical Adhesive