天津医药 ›› 2021, Vol. 49 ›› Issue (2): 195-198.doi: 10.11958/20202405

• 应用研究 • 上一篇    下一篇

伴髓样特征乳腺癌与乳腺纤维腺瘤超声表现的影像组学对比研究 #br#

张宇,刘梁生,马文娟,路红,刘佩芳,朱鹰
  

  1. 天津医科大学肿瘤医院乳腺影像诊断科,国家肿瘤临床医学研究中心,天津市“肿瘤防治”重点实验室,天津市恶性肿瘤临床医
    学研究中心,乳腺癌防治教育部重点实验室(邮编
    300060

  • 收稿日期:2020-08-27 修回日期:2020-11-08 出版日期:2021-02-15 发布日期:2021-02-02
  • 通讯作者: 朱鹰 E-mail:zhuying1881@msn.com
  • 基金资助:
    基于多模态影像表型的乳腺癌预后预测模型研究;Ⅰ~Ⅱ期乳腺浸润性导管癌超声特征与预后相关性研究;基于MRI影像组学特征的三阴与非三阴乳腺癌预测模型研究

Ultrasonographic radiomics in differential diagnosis of breast carcinoma with medullary features and breast fibroadenoma #br#

ZHANG Yu, LIU Liang-sheng, MA Wen-juan, LU Hong, LIU Pei-fang, ZHU Ying #br#   

  • Received:2020-08-27 Revised:2020-11-08 Published:2021-02-15 Online:2021-02-02

摘要: 目的对比伴髓样特征乳腺癌与乳腺纤维腺瘤超声影像组学特征,挖掘鉴别诊断的定量参数,为临床诊
疗提供影像学依据。
方法 收集20151月—201912月于天津医科大学肿瘤医院乳腺影像诊断科行乳腺超声检
查并经手术病理证实为伴髓样特征乳腺癌的
43个病变的超声图像。随机抽取同一时期行乳腺超声检查并经手术病
理证实为乳腺纤维腺瘤的
129个病变的超声图像作为对照组。分别提取2组超声图像的影像组学特征参数,比较2
组参数的差异,采用受试者工作特征(ROC)曲线分析差异有统计学意义的参数的诊断效能。 结果伴髓样特征乳腺
癌与乳腺纤维腺瘤相比纵横比更大(
0.623 vs. 0.495),凹性率更大(0.107 vs. 0.047),灰度均值更小(35.651 vs. 49.990),
相关性更小(
0.903 vs. 0.935),同质性更小(0.780 vs. 0.811),差异均有统计学意义(P0.01)。纵横比、凹性率和相关
性的曲线下面积及准确度相对较高,可达
0.70左右。纵横比、凹性率、灰度均值、相关性和同质性的敏感度均较高,
可达
0.80以上,但特异度均较低。 结论超声影像组学特征参数能为伴髓样特征乳腺癌与乳腺纤维腺瘤的鉴别诊
断提供依据,具有一定的临床意义。

关键词: 癌, 髓样, 乳腺肿瘤, 超声检查, 纤维腺瘤, 诊断, 鉴别, 影像组学

Abstract: Objective To compare the ultrasonographic radiomics features of breast carcinoma with medullary features
(CMF) and breast fibroadenoma (FA), and to comfirm the quantitative parameters of differential diagnosis so as to provide the
imaging basis for clinical diagnosis and treatment.
Methods Data of ultrasonographic images containing 43 CMF lesions
and 129 FA lesions (control group) confirmed by pathology from January 2015 to December 2019 were retrospectively
analyzed. Radiomics features were evaluated and compared between the two groups. The area under the curve, cut-off value,
accuracy, sensitivity, specificity, positive predictive value and negative predictive value were calculated.
Results The
aspect ratio (0.623
vs. 0.495) and concavity rate (0.107 vs. 0.047) were higher in CMF group than those of FA group. The gray
mean value (35.651
vs. 49.990), correlation (0.903 vs. 0.935) and homogeneity (0.780 vs. 0.811) were lower in CMF group
than those of FA group (
P0.01). The AUC and accuracy of aspect ratio, concavity rate and correlation were relatively
higher, which can reach to 0.70. The sensitivity of aspect ratio, concavity rate, gray mean value, correlation and homogeneity
were higher, and which can be up to 0.80, but the specificity was lower.
ConclusionThe aspect ratio, concavity rate, gray
mean value, correlation and homogeneity of ultrasonographic radiomics features provide evidence for the differential
diagnosis of breast carcinoma with medullary features and breast fibroadenoma, and which has certain clinical significance.

Key words: carcinoma, medullary, breast neoplasms, ultrasonography, fibroadenoma, diagnosis, differential, radiomics