天津医药 ›› 2025, Vol. 53 ›› Issue (6): 670-672.doi: 10.11958/20250019

• 药物临床观察 • 上一篇    

雄激素性秃发患者对酮康唑洗剂和二硫化硒洗剂过敏风险分析

王英1,2(), 杨顶权1,2,()   

  1. 1 中日友好医院皮肤科(邮编100029)
    2 中日友好医院国家中西医结合医学中心
  • 收稿日期:2025-01-02 修回日期:2025-03-30 出版日期:2025-06-15 发布日期:2025-06-20
  • 通讯作者: E-mail:ydqlx@163.com
  • 作者简介:王英(1987),女,主治医师,主要从事毛发疾病、过敏性疾病、银屑病方面研究。E-mail:dr_wy@hotmail.com

Risk analysis of allergy to ketoconazole shampoo and selenium sulfide shampoo in patients with androgenetic alopecia

WANG Ying1,2(), YANG Dingquan1,2,()   

  1. 1 Department of Dermatology, China-Japan Friendship Hospital, Beijing 100029, China
    2 National Center for Integrative Medicine, China-Japan Friendship Hospital
  • Received:2025-01-02 Revised:2025-03-30 Published:2025-06-15 Online:2025-06-20
  • Contact: E-mail: ydqlx@163.com

摘要:

目的 分析雄激素性秃发(AGA)患者接触酮康唑洗剂和二硫化硒洗剂的过敏反应发生率。方法 对683例AGA患者进行了回顾性分析,依据病历资料、皮肤镜检查、真菌检查及斑贴试验结果,记录伴发脂溢性皮炎患者人数、马拉色菌检测阳性患者人数,及对酮康唑洗剂和二硫化硒洗剂接触过敏人数,分别计算上述指标的发生率或阳性率。结果 AGA患者中脂溢性皮炎发生率为65.59%,马拉色菌阳性率为42.02%。在AGA患者中酮康唑洗剂的过敏率为34.70%,明显高于二硫化硒洗剂的25.62%(P<0.01)。伴发脂溢性皮炎和马拉色菌阳性的AGA患者中,酮康唑洗剂过敏率高于二硫化硒洗剂(P<0.05)。脂溢性皮炎患者中马拉色菌阳性率为45.98%,高于非脂溢性皮炎患者中的34.47%(P<0.01)。结论 对于AGA患者,接触酮康唑洗剂相比二硫化硒洗剂具有更高的过敏风险,使用过程中应避免抗真菌洗剂长期使用,必要时采用斑贴试验进行药敏检测。

关键词: 秃发, 皮炎, 脂溢性, 二硫化物类, 硒, 酮康唑, 皮炎, 接触性

Abstract:

Objective To analyze the incidence of contact allergic reactions to ketoconazole shampoo and selenium sulfide shampoo in patients with androgenetic alopecia (AGA). Methods A retrospective analysis was conducted on 683 AGA patients. Based on medical records, dermoscopy findings, fungal examinations and patch test results, the number of patients with seborrheic dermatitis, Malassezia-positive cases and contact allergy to ketoconazole and selenium sulfide shampoos were recorded. Results The incidence of seborrheic dermatitis in AGA patients was 65.59%, and the Malassezia-positive rate was 42.02%. The allergy rate to ketoconazole shampoo in AGA patients was 34.70%, which was significantly higher than the 25.62% allergy rate to selenium sulfide shampoo (P<0.01). In AGA patients with concomitant seborrheic dermatitis and Malassezia positivity, the allergy rate to ketoconazole lotion was higher than that to selenium sulfide lotion (P<0.05). The positivity rate of Malassezia was 45.98% in seborrheic dermatitis patients, which was higher than that of the 34.47% in non-seborrheic dermatitis patients (P<0.01). Conclusion In patients with AGA, ketoconazole shampoo carries a higher allergy risk compared to selenium sulfide shampoo. Long-term use of antifungal shampoos should be avoided in patients with AGA and conduct patch tests for drug detection when necessary.

Key words: alopecia, dermatitis, seborrheic, disulfides, selenium, ketoconazole, dermatitis, contact

中图分类号: