
Tianjin Medical Journal ›› 2024, Vol. 52 ›› Issue (10): 1056-1060.doi: 10.11958/20240043
• Clinical Research • Previous Articles Next Articles
MENG Keqing(
), ZHANG Wulin, DONG Wei, XU Yanhui, LI Nan
Received:2024-01-08
Revised:2024-05-08
Published:2024-10-15
Online:2024-10-14
MENG Keqing, ZHANG Wulin, DONG Wei, XU Yanhui, LI Nan. Effect of phacoemulsification combined with CTR implantation on capsule stability after cataract surgery for high myopia[J]. Tianjin Medical Journal, 2024, 52(10): 1056-1060.
CLC Number:
| 组别 | 年龄/岁 | 性别 (男/女) | 角膜 曲率/D | 眼轴长 度/mm | 晶状体核硬度 分级(Ⅱ/Ⅲ/Ⅳ) |
|---|---|---|---|---|---|
| 对照组 | 64.8±5.5 | 20/20 | 47.34±0.75 | 28.57±0.62 | 23/11/6 |
| 试验组 | 65.5±5.2 | 20/20 | 47.48±0.83 | 28.72±0.81 | 20/14/6 |
| t或χ2 | 0.544 | 0.000 | 0.792 | 0.930 | 0.569 |
Tab.1 Comparison of preoperative baseline data between the two groups
| 组别 | 年龄/岁 | 性别 (男/女) | 角膜 曲率/D | 眼轴长 度/mm | 晶状体核硬度 分级(Ⅱ/Ⅲ/Ⅳ) |
|---|---|---|---|---|---|
| 对照组 | 64.8±5.5 | 20/20 | 47.34±0.75 | 28.57±0.62 | 23/11/6 |
| 试验组 | 65.5±5.2 | 20/20 | 47.48±0.83 | 28.72±0.81 | 20/14/6 |
| t或χ2 | 0.544 | 0.000 | 0.792 | 0.930 | 0.569 |
| 组别 | UCVA | |||
|---|---|---|---|---|
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |
| 对照组 | 1.73±0.34 | 0.83±0.21a | 0.76±0.19a | 0.73±0.17a |
| 试验组 | 1.72±0.42 | 0.82±0.22a | 0.74±0.23a | 0.62±0.14a |
| t | 0.175 | 0.175 | 0.350 | 1.926 |
| 组别 | BCVA | |||
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |
| 对照组 | 1.88±0.32 | 0.92±0.42a | 0.84±0.26a | 0.78±0.32a |
| 试验组 | 1.86±0.31 | 0.81±0.36a | 0.76±0.32a | 0.62±0.41a |
| t | 0.284 | 2.151* | 3.882* | 2.764* |
Tab.2 Comparison of uncorrected visual acuity values at different time points between two groups
| 组别 | UCVA | |||
|---|---|---|---|---|
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |
| 对照组 | 1.73±0.34 | 0.83±0.21a | 0.76±0.19a | 0.73±0.17a |
| 试验组 | 1.72±0.42 | 0.82±0.22a | 0.74±0.23a | 0.62±0.14a |
| t | 0.175 | 0.175 | 0.350 | 1.926 |
| 组别 | BCVA | |||
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |
| 对照组 | 1.88±0.32 | 0.92±0.42a | 0.84±0.26a | 0.78±0.32a |
| 试验组 | 1.86±0.31 | 0.81±0.36a | 0.76±0.32a | 0.62±0.41a |
| t | 0.284 | 2.151* | 3.882* | 2.764* |
| 组别 | ARTh | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |||||||
| 对照组 | 520.5±7.4 | 520.5±4.9 | 532.1±5.3a | 530.1±6.3a | ||||||
| 试验组 | 523.3±6.2 | 521.4±2.5 | 531.3±3.2a | 528.5±7.6a | ||||||
| t | 1.829 | 1.033 | 0.812 | 1.025 | ||||||
| 组别 | SP-A1 | |||||||||
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |||||||
| 对照组 | 100.5±4.2 | 102.3±5.9 | 101.1±3.1 | 103.1±3.7a | ||||||
| 试验组 | 100.1±2.2 | 103.4±2.3a | 102.3±3.1a | 102.5±1.6a | ||||||
| t | 0.530 | 1.103 | 1.717 | 0.940 | ||||||
| 组别 | CBI | |||||||||
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |||||||
| 对照组 | 0.11±0.03 | 0.13±0.03a | 0.12±0.01 | 0.13±0.03 | ||||||
| 试验组 | 0.12±0.03 | 0.14±0.04a | 0.13±0.02 | 0.12±0.02 | ||||||
| t | 1.491 | 1.265 | 2.828** | 1.754 | ||||||
Tab.3 Comparison of ARTh, SP-A1 and CBI at different time points between the two groups
| 组别 | ARTh | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |||||||
| 对照组 | 520.5±7.4 | 520.5±4.9 | 532.1±5.3a | 530.1±6.3a | ||||||
| 试验组 | 523.3±6.2 | 521.4±2.5 | 531.3±3.2a | 528.5±7.6a | ||||||
| t | 1.829 | 1.033 | 0.812 | 1.025 | ||||||
| 组别 | SP-A1 | |||||||||
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |||||||
| 对照组 | 100.5±4.2 | 102.3±5.9 | 101.1±3.1 | 103.1±3.7a | ||||||
| 试验组 | 100.1±2.2 | 103.4±2.3a | 102.3±3.1a | 102.5±1.6a | ||||||
| t | 0.530 | 1.103 | 1.717 | 0.940 | ||||||
| 组别 | CBI | |||||||||
| 术前 | 术后1个月 | 术后3个月 | 术后6个月 | |||||||
| 对照组 | 0.11±0.03 | 0.13±0.03a | 0.12±0.01 | 0.13±0.03 | ||||||
| 试验组 | 0.12±0.03 | 0.14±0.04a | 0.13±0.02 | 0.12±0.02 | ||||||
| t | 1.491 | 1.265 | 2.828** | 1.754 | ||||||
| 组别 | 对比敏感度/cpd | 前囊口面积/mm2 | IOL倾斜角/° | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 术后1个月 | 术后3个月 | 术后6个月 | 术后1个月 | 术后3个月 | 术后6个月 | 术后1个月 | 术后3个月 | 术后6个月 | |||
| 对照组 | 1.58±0.17 | 1.75±0.21a | 1.63±0.14ab | 26.67±3.84 | 24.13±2.62 | 21.53±2.71 | 3.77±0.94 | 3.94±0.62 | 4.32±0.75a | ||
| 试验组 | 1.62±0.12 | 1.73±0.10a | 1.65±0.18 | 28.12±3.57 | 26.63±2.87 | 25.15±2.96 | 3.42±0.93 | 3.53±0.87 | 3.75±0.96 | ||
| t | 1.216 | 0.544 | 0.555 | 1.749 | 4.069** | 5.705** | 1.674 | 2.427* | 2.959** | ||
Tab.4 Comparison of contrast sensitivity, anterior capsular orifice area and IOL tilt angle between the two groups at different post-treatment time points
| 组别 | 对比敏感度/cpd | 前囊口面积/mm2 | IOL倾斜角/° | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 术后1个月 | 术后3个月 | 术后6个月 | 术后1个月 | 术后3个月 | 术后6个月 | 术后1个月 | 术后3个月 | 术后6个月 | |||
| 对照组 | 1.58±0.17 | 1.75±0.21a | 1.63±0.14ab | 26.67±3.84 | 24.13±2.62 | 21.53±2.71 | 3.77±0.94 | 3.94±0.62 | 4.32±0.75a | ||
| 试验组 | 1.62±0.12 | 1.73±0.10a | 1.65±0.18 | 28.12±3.57 | 26.63±2.87 | 25.15±2.96 | 3.42±0.93 | 3.53±0.87 | 3.75±0.96 | ||
| t | 1.216 | 0.544 | 0.555 | 1.749 | 4.069** | 5.705** | 1.674 | 2.427* | 2.959** | ||
| [1] | HEKALO Z, MOHAMED Z, LHUILLIER L, et al. Retinal detachment in high myopia after cataract surgery:retrospective study about 365 case[J]. Invest Ophthalmol Vis Sci, 2019, 60(9):493. |
| [2] | ELHUSSEINY A M, SALIM S. Cataract surgery in myopic eyes[J]. Curr Opin Ophthalmol, 2023, 34(1):64-70. doi:10.1097/ICU.0000000000000914. |
| [3] | CHONG E W, MEHTA J S. High myopia and cataract surgery[J]. Curr Opin Ophthalmol, 2016, 27(1):45-50. doi:10.1097/ICU.0000000000000217. |
| [4] | CIONNI R J, OSHER R H. Endocapsular ring approach to the subluxed cataractous lens[J]. J Cataract Refract Surg, 1995, 21(3):245-249. doi:10.1016/s0886-3350(13)80126-5. |
| [5] | 中华医学会眼科学分会白内障与人工晶体学组. 第16届全国白内障及人工晶体学术会议纪要[J]. 中华眼科杂志, 2014, 50(9):719-720. |
| Cataract and IOL Group of the Ophthalmology Branch of the Chinese Medical Association. Minutes of the 16th National Conference on Cataract and Intraocular Lenses[J]. Chinese Journal of Ophthalmology, 2014, 50(9):719-720. | |
| [6] | VINCIGUERRA R, AMBRÓSIO R Jr, ELSHEIKH A, et al. Detection of keratoconus with a new biomechanical index[J]. J Refract Surg, 2016, 32(12):803-810. doi:10.3928/1081597X-20160629-01. |
| [7] | 李鹤一, 于杰, 刘厉严. 白内障超声乳化吸出并散光矫正型多焦点人工晶体植入术对老年白内障病人角膜散光及视觉质量的影响[J]. 实用老年医学, 2020, 34(6):547-550. |
| LI H Y, YU J, LIU L Y. The effect of cataract phacoemulsification with toric multifocal intraocular lens implantation on corneal astigmatism and visual quality in elderly patients[J]. Practical Geriatrics, 2020, 34(6):547-550. doi:10.3980/j.issn.1672-5123.2019.1.18. | |
| [8] | DU R, XIE S, IGARASHI-YOKOI T, et al. Continued increase of axial length and its risk factors in adults with high myopia[J]. JAMA Ophthalmol, 2021, 139(10):1096-1103. doi:10.1001/jamaophthalmol.2021.3303. |
| [9] | 孟娜娜, 夏磊洲, 赵治, 等. 不同形态白内障和视觉质量的相关性研究[J]. 临床眼科杂志, 2021, 29(5):403-405. |
| MENG N N, XIA L Z, ZHAO Z, et al. Correlation between different types of cataract and visual quality[J]. Journal of Clinical Ophthalmology, 2021, 29(5):403-405. doi:10.3969/j.issn.1006-8422.2021.05.005. | |
| [10] | 王志亮, 赵毅, 霍涛, 等. 精细化囊膜处理对衍射型多焦点人工晶体视觉质量的影响[J]. 国际眼科杂志, 2020, 20(10):1806-1808. |
| WANG Z L, ZHAO Y, HUO T, et al. The effect of refined capsular management on the visual quality of diffractive multifocal intraocular lenses[J]. International Journal of Ophthalmology, 2020, 20(10):1806-1808. | |
| [11] | AKIYAMA A, YOKOTA H, ASO H, et al. Comparison of postoperative stability of intraocular lenses after phacovitrectomy for rhegmatogenous retinal detachment[J]. J Clin Med, 2022, 11(12):3438. doi:10.3390/jcm11123438. |
| [12] | WANG L, GUIMARAES DE SOUZA R, WEIKERT M P, et al. Evaluation of crystalline lens and intraocular lens tilt using a swept-source optical coherence tomography biometer[J]. J Cataract Refract Surg, 2019, 45(1):35-40. doi:10.1016/j.jcrs.2018.08.025. |
| [13] | YANG S, JIANG H, NIE K, et al. Effect of capsular tension ring implantation on capsular stability after phacoemulsification in patients with weak zonules: a randomized controlled trial. CTR implantation in cataract patients with weak zonules[J]. BMC Ophthalmol, 2021, 21(1):19. doi:10.1186/s12886-020-01772-8. |
| [14] | HUANG Y, ZHANG T, WEI Q, et al. "NIR-triggered ROS storage" photodynamic intraocular implant for high-efficient and safe posterior capsular opacification prevention[J]. Asian J Pharm Sci, 2022, 17(6):838-854. doi:10.1016/j.ajps.2022.10.004. |
| [15] | 耿文静, 管宇, 李鹏飞, 等. 高度近视并发性白内障患者房水中细胞因子的检测分析[J]. 眼科新进展, 2021, 41(11):1031-1036. |
| GENG W J, GUAN Y, LI P F, et al. Analysis of cytokines in aqueous humor of patients with high myopia compli-cated cataract[J]. Recent Advances in Ophthalmology, 2021, 41(11):1031-1036. doi:10.13389/j.cnki.rao.2021.0217. | |
| [16] | 赵抒羽, 何锦贤, 吴燕纯, 等. OPD-ScanⅢ型像差分析仪评估高度近视合并白内障患者植入三焦点IOL术后视觉质量[J]. 国际眼科杂志, 2022, 22(2):318-321. |
| ZHAO S Y, HE J X, WU Y C, et al. Clinical application of OPD - Scan Ⅲ aberration analyzer in evaluating the implantation of trifocal intraocular lens in patients with high myopia complicated with cataract[J]. International Eye Science, 2022, 22(2):318-321. doi:10.3980/j.issn.1672-5123.2022.2.28. | |
| [17] | 刘国颖, 邵东平, 吴玉萍. 散瞳对白内障合并高度近视患者眼球生物学测量和IOL度数计算的影响[J]. 国际眼科杂志, 2021, 21(1):144-147. |
| LIU G Y, SHAO D P, WU Y P. The impact of mydriasis on biometric measurements and IOL power calculations in patients with cataract and high myopia[J]. International Journal of Ophthalmology, 2021, 21(1):144-147. | |
| [18] | LORENTE R, DE ROJAS V, VAZQUEZ DE PARGA P, et al. Management of late spontaneous in-the-bag intraocular lens dislocation: Retrospective analysis of 45 cases[J]. J Cataract Refract Surg, 2010, 36(8):1270-1282. doi:10.1016/j.jcrs.2010.01.035. |
| Viewed | ||||||
|
Full text |
|
|||||
|
Abstract |
|
|||||